Special Valve for fine dosing to prevent formation of bridges with continuous support and gas-tight shut-off of bulk and granules.
- Range of Nominal Widths: DN 100 – DN 400
- Operating Temperature: – 40°C to + 200°C*
- Pressure range: max. 6 bar*
- Sleeve: replaceable or fix vulcanized
DN | A | B | (R) | BL | rotary disc | actuator | DI | Dv | Db | (H) |
---|---|---|---|---|---|---|---|---|---|---|
100 | 135 | 95 | 154 | 39 | 6-flaps | DR 60 U 180° | 291 | 51 | 108 | 475 |
150 | 175 | 135 | 218 | 56 | 6-flaps | DR 150 U 180° | 372 | 63 | 136 | 595 |
200 | 200 | 160 | 273 | 54 | 6-flaps | DR 150 U 180° | 372 | 63 | 136 | 645 |
250 | 249 | 207 | 314 | 68 | 8-flaps | DR 300 U 180° | 483 | 77 | 166 | 743 |
300 | 274 | 232 | 370 | 78 | 8-flaps | DR 300 U 180° | 483 | 77 | 166 | 793 |
350 | 305 | 258 | 423 | 78 | 8-flaps | DR 600 U 180° | 611 | 93 | 202 | 889 |
400 | 329 | 303 | 473 | 102 | 8-flaps | DR 600 U 180° | 611 | 93 | 202 | 958 |
We reserve all rights and changes
Note: For flange dimensions please see technical data
() = May vary
Driving selection according to different operating conditions
* Operational limitations depend on nominal width, temperature and composite materials. Crucial are the parameters set in the confirmation.